[HTML][HTML] Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT

DT Tai, LT Oanh, PH Phuong, A Sulieman… - Saudi Journal of …, 2022 - Elsevier
… The 3D-CRT and JO-IMRT plans had average doses to the … , for the 3D-CRT and JO-IMRT
designs, the average doses to … For the 3D-CRT and JO-IMRT designs, the CI and HI were …

[HTML][HTML] … toxicity profile between three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) in locally advanced head and neck …

N Kucha, TP Soni, N Jakhotia, N Patni, DK Singh… - Cancer treatment and …, 2020 - Elsevier
… were treated with IMRT and 40 patients with 3DCRT to dose of 70 Gy … All patients were
assessed weekly during … to patients who received IMRT for locally advanced head neck cancer. …

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

DK Ismael, FF Hassan - Hospital Practices and Research, 2020 - jhpr.ir
3D-CRT and IMRT were used to produce the maximum dose of target volume coverage and
minimum dose … Data analysis was performed using the available statistical package of SPSS …

[PDF][PDF] Evaluation of Radiation Doses Received by Organs at Risk in 3D Conformal and Intensity Modulated Radiotherapy for Head and Neck Cancer

HA Hassan, KA Faraj, ZY Saeed - … of Zankoy Sulaimani-Part A, 2019 - researchgate.net
… the doses delivered to the critical structures located close to the target volume during head
and neck radiotherapy by 3D-CRT and IMRT … and hypopharynx", Head Neck. Vol. 12, No. …

… comparison between three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in the treatment of different stages of …

MS Ibrahim, EM Attalla, M El Naggar… - … of Radiotherapy in …, 2019 - cambridge.org
… The dose delivered to PTV1 and PTV2 for 3D-CRT and 7F-IMRT are statistically similar, …
9F-IMRT is significantly better than 3D-CRT. For organs at risk (OARs), the delivered dose is …

… -modulated radiation therapy versus three-dimensional conformal radiotherapy in head and neck squamous cell carcinoma: long-term and mature outcomes of a …

T Gupta, S Sinha, S Ghosh-Laskar, A Budrukkar… - Radiation …, 2020 - Springer
… Patients were treated with 6MV photons to a total dose of 70Gy/35 fractions over 7 weeks
(3D-CRT) or 66Gy/30 fractions over 6 weeks (IMRT). A sample size of 60 patients was …

Verification and Evaluation of Radiation Doses received by organs at risk in (3D-CRT) and IMrt technique for breast cancer

NK Abdulkareem, FF Hassan… - Journal of Physics …, 2020 - iopscience.iop.org
… the outcome of Radiation Treatment Plans (RTP) of left-… IMRT technique, and 3D-CRT
technique to organs at risk (OAR) that are proximal to the target volume during breast radiotherapy. …

Xerostomia and clinical outcomes in definitive intensity modulated radiotherapy (IMRT) versus three-dimensional conformal radiotherapy (3D-CRT) for head and neck …

F De Felice, N Pranno, P Papi, O Brugnoletti… - in vivo, 2020 - iv.iiarjournals.org
… ) technique is currently considered standard in RT treatment plans, mainly because of its
ability to better limit the dose to adjacent organs at risk over three-dimensional conformal RT (…

[PDF][PDF] Assessment of developed IMRT and 3D-CRT planning protocols for treating nasopharyngeal cancer patients based on the target and organs at risks common …

G Sharbo, B Hashemi, M Bakhshandeh… - International Journal of …, 2022 - sid.ir
3D-CRT technique can be attributed to the increased doses of … Radiation Therapy Oncology
Group. RTOG 0615: a phase II … using three – dimensional conformal radiotherapy (3D-CRT) …

… -dimensional conformal radiotherapy versus intensity modulated radiotherapy with simultaneous integrated boost in the treatment of locally advanced head and neck …

M Jirkovska, T Novak, B Malinova, R Lohynska - Neoplasma, 2019 - search.ebscohost.com
… No statistically significant differences in LCR and OS were found in our study between
the 3D-CRT and IMRT-SIB groups, despite the higher dose delivered to the GTV in patients …